Application:
1. Can be used in Zone 1 and Zone 2 dangerous places.
2. Can be used in II A、II B explosive atmosphere.
Mode implication
Feature
1. The fan is fabricated of motor, leaves, cylinder,etc.
2. Suitable for steel pipe and cable wiring.
3. Installation types:bracket type, fixed type, fixed type, pipe type and wall type.
4. Suitable for Gb3836, IEC60079 standard.
Main technical parameters:
1. Ex- mark: Exd ⅡB T4 Gb
2. Protection grade: IP54
3. Corrosion-proof grade: WF1
4. Rated voltage: AC220V/380V
5. Cycle speed of shafet: 1450r/min
6. Cable 's specification: φ10mm~φ14mm
7. Ingress thread specification: G3/4"
8. Impeller diameter/Power/Wind flow/weight:
300mm/0.25kW/2280m3/h/16kg
400mm/0.37kW/2880m3/h/19kg
500mm/0.55kW/5900m3/h/23kg
600mm/0.75kW/8700m3/h/28kg
Outline example
型号Type
|
A
|
B
|
C
|
BAF-300
|
315
|
310
|
350
|
BAF-400
|
315
|
410
|
450
|
BAF-500
|
315
|
510
|
550
|
BAF-600
|
315
|
610
|
650
|
|